Custom PC Industrial Flow Cytometer Sample Carousel

Material: ABS/POM/PA66/PP/PC/PA/PU/TPE/TPU etc.
Processing Service: Injection
Drawing Format: STP, STEP, IGS
Contact: amanda@tjswks.com / 0086-15222707659
Send Inquiry
Description

Tianjin SWKS Technology & Development Co.,Ltd is one of the most reliable manufacturers and suppliers of custom pc industrial flow cytometer sample carousel in China. If you're going to buy bulk cheap custom pc industrial flow cytometer sample carousel, welcome to get quotation from our factory. Quality products and low price are available.

 

Indexed Specimen Tube Carrier for an Automated Flow Cytometer

This made-to-drawing polycarbonate carousel holds the customer's approved specimen tubes at individual indexed locations. Order it as part of a defined instrument configuration with vertical seating, angular position and access matched to the instrument. The photographs are generated design illustrations.

Tube pitch and loading map

The carousel presents vertical tubes around an indexed axis, with an individual location for each holder. Include actual tube and cap options, intended loading direction, reference number position and any positions reserved by the cytometer manufacturer.

For equipment procurement, the physical difference between this carrier and an analyzer tray is the ring of upright positions indexed about a center spindle. Start by plotting every seat center in polar coordinates using the equipment builder's origin. If a software station number appears in an OEM drawing, preserve a separate cross-reference to the number marked on the carousel. A fit report should state which physical pocket was tested. Stacking two tubes next to each other may also reveal an interference between wide caps that a single sample check misses. Bring both container heights and widths to the first review.

Write a container matrix instead of listing tube volume alone. Ask for the bottom style, actual outside profile, cap or collar, and the label envelope of every approved container. A tube with a side label may bind in a pocket while an unmarked unit enters freely. If the operator uses a carrier insert for narrow tubes, include the insert identification and fitted clearances on the customer drawing. Sample which pockets receive the largest allowed container rather than measuring them all with the narrowest one. Keep any temporary mock tube tagged as a test gauge so it does not become an apparent production vessel.

Home reference and station alignment

Identify the reference post, home flag or encoder mating part on the approved machine. Check the nominal tube center at each reading station around the cycle. An outside circumference measurement does not establish the location of an individual tube.

An ambiguous home reference can make a good pocket look like the wrong pocket during a review. Draw one radial centerline through a physical key and a second through the primary sample position. Name both and indicate the installed relationship. Where the index ring and carrier use independent fasteners, include the relative location after installation. A fixture useful for supplier inspection can reproduce the hub seat and verify multiple pocket positions without needing to run an instrument. Keep the reference detector or indexing device in the system documentation.

Where the carousel must make a full turn, check axial runout and radial location with the reference spindle engaged. Use multiple positions around the ring and record how the measurement fixture holds the center. If the machine normally relies on a removable center fastener, use its approved fastened condition for the trial. Isolate eccentricity between a dimensional fault in the part and misalignment in the hub model. Positioning errors should be understandable in terms of what the sample presentation station actually sees.

Tube pockets and central index interface

Vertical stop and tip access envelope

Show where the tube seats and the available clearance to the instrument's probe or loading fork. An apparently small change in tube cap height can shift the closest approach condition. Record the assembled sample presentation rather than assuming all containers sit at the same level.

Describe the tube at its actual seat and identify whether its shoulder, lip or closed end touches the carousel. A shallow change at the lip may tilt the assembly while a photograph from above still looks centered. Check two points on a tall reference tube to distinguish lean from sideways offset. Where the intended tube has a raised cap edge, view the approach area in a side section. Preserve the model of any lifting guide that touches the carrier in the instruments covered by the order.

Tube access belongs to the complete automated instrument. In a physical fit sample, document how the tube can enter and leave the seat after the neighboring pockets are populated. Look for interference from tall caps or nearby cover features during placement. Compare a tube initially placed with one that has completed the approved handling cycle. If the customer removes the carousel as part of service, record the safe equipment state and observe the installed position again after it is refitted. The sample report can include still images of those positions.

Cleaning and optical appearance

Grade and cleaning requirements depend on the owner's operational conditions. Transparent or tinted PC is a design choice whose cosmetic references must be documented. This molding is a positioning component and supplies no assay or diagnostic performance claim.

With clear PC, define whether a feature is clear for visual inspection or purely for molded appearance. A frosted rib or mold witness may be acceptable under a supported holder and unacceptable where staff need to see positioning marks. Review the empty carrier with its intended background, then add populated holders and inspect again. Collect cleaning acceptance after the customer's service procedure. Document whether a residue, dulling or a physical crack was observed and where it appeared on the carrier.

If the instrument uses an optical reference on the carousel, show the actual reading-side surface and its background. Where a tag is present, it can be a separate item from the visual shade of the molded part. Specify whether a bright window reflection would make it harder for an operator to see the index. Document the expected cleanup and set the appearance criteria with the customer. An engineering sample can be judged from the normal viewpoint under a fixed lamp arrangement, then checked again after approved conditioning. This makes it possible to distinguish a molded appearance issue from residue left at a pocket.

Sample identity and carousel retention

Confirm the center hub orientation and the features that prevent unintended lift in the approved mechanism. Keep an observed anomaly indexed to a specific pocket so tubes can be exchanged for isolation. Do not assign a missed detection to the carousel until equipment checks agree.

A trailing cable or reusable probe occupies separate space around the machine's cycle. The controls, measurements and prompts belong to the instrument builder. To check the molded interface, label a known sample holder, place it at a defined station, and capture the installed orientation alongside the numbered pocket. If the holder can rock excessively in only one position, record that position and compare it against an approved master using the same support stack. Molding review addresses repeatability of the plastic component.

Look at the molded rib pattern and the exposed ends separately. A transit support may have to locate beneath a perimeter flange without pressing unsupported recesses. Put the shipping orientation on the packaging drawing and check that dividers do not move against the hub. For production inspection, ask the tool designer where to put trace marks so they can be read without rotating a new unit out of its approved transport position. Review the gate vestige and trim zone before specifying a part color. Those records allow procurement to separate a cosmetic or shipping claim from a poor seating report.

Carousel hub and specimen seating geometry

Model variation and approval specimens

List the tube families and instrument revisions each carousel must fit. Retain one verified set of tubes with the sample when useful. If more than one capacity is offered, specify the pocket count, orientation reference and color on the matching purchase records.

Create a table of known instrument attachments before the mechanical sample is ordered. Each row should identify the carrier capacity, the mating spindle revision and the designated sample container. Reserve reusable fit pieces to accompany any later drawing changes. This avoids repeating all the study work for a second customer build with a similar product name. Ask whether the site needs a shipping insert that keeps the center hub clear of load and prevents cap seats from rubbing against the carton.

The receiving lot should be tied to a reference package used by the equipment manufacturer. Start with assembly STEP files and a controlled drawing showing each critical interface. Add accepted tube profiles and the criterion for pocket position, fit and appearance, and name the reference specimen for the overall assembly. Where a new instrument uses a different spindle with the same pocket count, give the change a new drawing suffix. A buyer can request a mold review, a small set of first articles and separate pricing for planned annual orders. Set design approval against the assembled fit state before committing to repeat volume.

Input package for the quotation

Item Input required
Carrier Pocket count and part drawing
Tube set Controlled container drawings with caps and envelopes
Instrument Spindle, handling housing and use location
Molding PC grade and appearance reference
Sampling Fit gauge, quantities and acceptance record

Other sample-handling fixtures include Custom PC Industrial Laboratory Analyzer Sample Tray and Custom ABS Industrial Laboratory Centrifuge Rotor Adapter.

Send approved machine and tube files to amanda@tjswks.com with the expected annual use and sample report scope.

Hot Tags: custom pc industrial flow cytometer sample carousel, China, suppliers, manufacturers, factory, bulk, cheap, low price, quotation, ABS PEEK Polycarbonate Plastic Shell Housing, consumer plastic injection parts, Custom Injection Molding Plastic Product PP Injection Molding Parts, Low Volume Injection Molding Machine, PE plastic part, POM machine parts